Welcome

Zyxel es-2108.ZyXEL Dimension ES-2108-G – switch – 8 ports – managed – desktop Series Specs

 

Zyxel es-2108.Download Landing

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Troubleshooting.: ZyXEL ESPWR 8-Port Layer 2 Managed Switch with PoE Support: Electronics

 

ZyXEL ES Layer 2 Managed 8-Port Fast Ethernet 10/ Switch Visit the ZyXEL Store. Currently unavailable. We don’t know when or if this item will be back in stock. This fits your. Make sure this fits by entering your model number. Fan-less design for noise-sensitive environment. Reminder: NBG To upgrade the firmware NBG V(ABMV.3)C0 or later, make sure to upgrade V(ABMV.2)C0 firmware in advance. GS Series. May What is the maximum MTU size for ESG? Apr Why does the ESG receive unicasts packets that are not sent to it, and gets the SNMP-OID and results in a crash and constant rebooting?

 

Zyxel es-2108.: ZyXEL ES Layer 2 Managed 8-Port Fast Ethernet 10/ Switch: Electronics

Zyxel communications ES Pdf User Manuals. View online or download Zyxel communications ES User Manual, Release Note. May What is the maximum MTU size for ESG? Apr Why does the ESG receive unicasts packets that are not sent to it, and gets the SNMP-OID and results in a crash and constant rebooting? ZyXEL ES Layer 2 Managed 8-Port Fast Ethernet 10/ Switch Visit the ZyXEL Store. Currently unavailable. We don’t know when or if this item will be back in stock. This fits your. Make sure this fits by entering your model number. Fan-less design for noise-sensitive environment.
 
 
related:
ZyXEL Communications ES-2108 User Manual
4 Year Office Equipment Protection Plan
Zyxel communications ES Manuals | ManualsLib
ZyXEL Communications ES-2108 Manuals
Product description
ZyXEL Dimension ESG – switch – 8 ports – managed – desktop Series Specs – CNET

Table of Contents. ES Series. Previous Page. Next Page. Chapters Table of Contents 9 List of Figures Troubleshooting Chapter 30 Troubleshooting Problems with the Password Zyxel communications ethernet switch quick start guide 43 pages.

Zyxel communications switch – ethernet switch user manual 88 pages. All rights reserved. Disclaimer ZyXEL does not assume any liability arising out of the application or use of any products, or software described herein.

Operation is subject to the following two conditions: 1 This switch may not cause harmful interference. During the warranty period, and Page 9: Table Of Contents 2. Page 11 Page 13 Page 15 Page Preface Settings and then click Control Panel. Page User Guide Feedback Help us help you. E-mail all User Guide-related comments, questions or suggestions for improvement to techwriters zyxel. Thank you. This allows the switch to maintain separate queues for packets from each individual source or flow and prevent a source from monopolizing the bandwidth.

In this example, all computers can share high-speed applications on the server. To expand the network, simply add more networking devices such as switches, routers, computers, print servers etc. Page High Performance Switched Example Ports in the same VLAN group share the same frame broadcast domain thus increase network performance through reduced broadcast traffic.

VLAN groups can be modified at any time by adding, moving or changing ports without any re-cabling. In this example, only ports that need access to the server need belong to VLAN 1.

Page Hardware Installation And Connection For proper ventilation, allow at least 4 inches 10 cm of clearance at the front and 3. This is especially important for enclosed rack installations.

Page Wall-Mounting Installation 5 Align the holes on the back of the switch with the screws on the wall. Hang the switch on the screws. Chapter 2 Hardware Installation and Connection to attach the second mounting bracket on the other side of the rack. Page Chapter 3 Hardware Overview This chapter describes the front panel and rear panel of the switch and shows you how to make the hardware connections. Fiber-Optic Use the fiber optic cable to connect this uplink port to a backbone Ethernet switche.

Check the LEDs to verify that it is functioning properly. Keep the dust cover on a fiber-optic module until you connect it. The link to a Mbps Ethernet network is up. The link to an Ethernet network is down.

Page The Web Configurator The date and time display as shown if you have not configured a time server nor manually entered a time and date in the General Setup screen. The following figure shows the navigating components of a web configurator screen. Click Management, Access Control and then Logins to display the next screen. Figure 19 Change Administrator Login Password 4.

Chapter 4 The Web Configurator for details. You have to log in with your password again after you log out. You can configure another IP address in a different subnet for management purposes. The following figure shows an example. Make sure your computer is in the same subnet as the switch.

Page System Status And Port Statistics To view the port statistics, click Status in all web configurator screens to display the Status screen as shown next. Port This identifies the Ethernet port. Click a port number to display the Port Details This field shows the power consumption of the powered device connected to the port.

Page 59 Poll Interval s The text box displays how often in seconds this screen refreshes. You may change the refresh interval by typing a new number in the text box and then clicking Set Interval. Stop Click Stop to stop port statistic polling. You can check the firmware version number and monitor the switch temperature, fan speeds and voltage on the ESPWR in this screen.

Page General Setup Set Interval. Stop Click Stop to halt statistic polling. This name consists of up to 32 printable characters; spaces are allowed. Page Introduction To Vlans In traditional switched environments, all broadcast packets go to each and every individual port. With VLAN, all broadcasts are confined to a specific broadcast domain. Note: VLAN is unidirectional; it only governs outgoing traffic. Chapter 7 Basic Setting Chapter 8 on page 73 for more information. Section 7. Cancel Click Cancel to reset the fields to your previous configuration.

This field displays the VLAN identification number of the network. Delete Click Delete to remove the selected entry from the summary table. Cancel Click Cancel to clear the Delete check boxes. Page 71 Select the check box to allow a powered device connected to the port to receive power from the switch. Apply Click Apply to save the settings. Page Port Vlan Trunking You may choose to accept both tagged and untagged type incoming frames or just tagged incoming frames on a port.

Port The port number identifies the port you are configuring. This is the default selection. The port-based VLAN setup screen is shown next. If it does not form a VLAN with a particular port then the switch cannot be managed from that port. Cancel Click Cancel to start configuring the screen again. Chapter 8 VLAN You may temporarily deactivate a rule without deleting it by clearing this check box.

This is for identification purpose only. Type the VLAN group identification number. It then displays in the summary table at the bottom of the screen. Page Figure 41 Spanning Tree Protocol: Status This is the number of times the spanning tree has been reconfigured. Times Time Since Last This is the time since the spanning tree was last reconfigured. Page 91 – see Apply Click Apply to save your changes back to the switch. Cancel Click Cancel to begin configuring this screen afresh.

Page Chapter 12 Bandwidth Control Select this check box to enable bandwidth control on the switch. Port This field displays the port number. Active Make sure to select this check box to activate bandwidth control on a port. If you enter a number between 64 and , the switch automatically rounds the number down to the nearest multiple of Page Broadcast Storm Control Select this check box to enable broadcast storm control on the switch.

Clear this check box to disable the feature. Port This field displays a port number. Rate Specify the traffic a port receives in Kilobits per second Kbps. Use this screen to select a mirror port and specify the traffic flow to be copied to the mirror port. Mirror Port The mirror port is the port you copy the traffic to in order to examine it in more detail without interfering with the traffic flow on the original port s.

Configure trunk groups or LACP before you connect the Ethernet switch to avoid causing network topology loops. System LACP system priority is a number between 1 and 65, The switch with the lowest Page Chapter 16 Port Authentication Windows operating system support. For other operating systems, see its documentation.