Welcome

Windows embedded device manager.Open Device Manager

 

Windows embedded device manager.Planning for client deployment to Windows Embedded devices in Configuration Manager

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Latest Products.Planning client deployment to Windows Embedded devices – Configuration Manager | Microsoft Docs

 

Apr 23,  · The Configuration Manager administrator (the Admin) reads how Windows Embedded devices uses write filters and how Configuration Manager can make this easier by automatically disabling and then re-enabling the writer filters to persist a software installation. For more information, see Planning for client deployment to Windows Embedded devices. Microsoft Windows Embedded Device Manager Client ML – software assurance – 1 user overview and full product specs on CNET. May 01,  · Embedded Lockdown Manager (ELM) is a tool that enables detection and configuration of lockdown features on Windows Embedded 8 Standard and Windows Embedded Industry devices. Warning: This site requires the use of scripts, which your browser does not currently allow.

 

Windows embedded device manager.Download Embedded Lockdown Manager from Official Microsoft Download Center

May 08,  · So it would appear that Windows Embedded Device Manager(WEDM) is now part of Configuration Manager SP1: And it doesn’t look like there’s a way to remove just what used to be WEDM, and the customer is not willing to remove Configuration Manager. Windows® Embedded Device Manager enables OEMs or their end customers to assess, update and even reimage Windows Embedded devices from a remote management server. This solution is an add-on to System Center Configuration Manager and is tailored for managing embedded devices. Aug 12,  · How to Open Device Manager via Control Panel Open Control Panel. In Windows 10 and Windows 8, assuming you’re using a keyboard or mouse, the fastest way is through the Power User Menu —just press the WIN (Windows) key and the X key ted Reading Time: 4 mins.
 
 
related:
Microsoft Windows Embedded Device Manager Client ML – software assurance Series Specs
Thank you for your feedback!
Microsoft Windows Embedded Device Manager Client ML – software assurance Series Specs – CNET
How to Open Device Manager
Our Design Intentions for Write Filter Management in Configuration Manager SP1
Example scenario – deploy Windows Embedded clients – Configuration Manager | Microsoft Docs

This scenario demonstrates how you can manage write-filter-enabled Windows Embedded devices with Configuration Manager. If your embedded devices do not support write filters, they behave as standard Configuration Manager clients and these procedures don’t apply.

The building for the new visitor center is not close to the IT department, so the kiosks must be managed remotely. In addition to the software that runs the presentations, these devices must run up-to-date antimalware protection software to comply with the company security policies. The kiosks must run 7 days a week, with no downtime while the visitor center is open.

Coho already runs Configuration Manager to manage devices on their network. Configuration Manager is configured to run Endpoint Protection, and install software updates and applications. However, because the IT team has not managed Windows Embedded devices before, the Configuration Manager administrator runs a pilot to manage two kiosks in the reception lobby. To manage these Windows Embedded devices that are write-filter-enabled, Configuration Manager administrator performs the following steps to install the Configuration Manager client, protect the client by using Endpoint Protection, and install the interactive presentation software.

The Configuration Manager administrator the Admin reads how Windows Embedded devices uses write filters and how Configuration Manager can make this easier by automatically disabling and then re-enabling the writer filters to persist a software installation.

For more information, see Planning for client deployment to Windows Embedded devices. Before the Admin installs the Configuration Manager client, the Admin creates a new query-based device collection for the Windows Embedded devices.

Because the company uses standard naming formats to identify their computers, the Admin can uniquely identify Windows Embedded devices by the first six letters of the computer name: WEMDVC. This collection allows the Admin to manage the Windows Embedded devices with different configuration options from the other devices.

The Admin will use this collection to control restarts, deploy Endpoint Protection with client settings, and deploy the interactive presentation application. See How to create collections. The Admin configures the collection for a maintenance window to ensure that restarts that might be required for installing the presentation application and any upgrades do not occur during opening hours for the visitor center.

Opening hours will be through , Monday through Sunday. The Admin configures the maintenance window for every day, through For more information, see How to use maintenance windows. The Admin then configures a custom device client setting to install the Endpoint Protection client by selecting Yes for the following settings, and then deploys this custom client setting to the Windows Embedded device collection:. For Windows Embedded devices with write filters, commit Endpoint Protection client installation requires restart.

Allow Endpoint Protection client installation and restart to be performed outside maintenance windows. When the Configuration Manager client is installed, these settings install the Endpoint Protection client and ensure that it is persisted in the operating system as part of the installation, rather than written to the overlay only.

The company security policies require that the antimalware software is always installed and the Admin does not want to run the risk of the kiosks being unprotected for even a short period of time if they restart.

The restarts that are required to install the Endpoint Protection client are a one-time occurrence, which happen during the setup period for the devices and before the visitor center is operational. Unlike the periodic deployment of applications or software definition updates, the next time the Endpoint Protection client is installed on the same device will probably be when the company upgrades to the next version of Configuration Manager.

For more information, see Configuring Endpoint Protection. With the configuration settings for the client now in place, the Admin prepares to install the Configuration Manager clients. Before the Admin can install the clients, they must manually disable the write filter on the Windows Embedded devices. The Admin reads the OEM documentation that accompanies the kiosks and follows their instructions to disable the write filters.

The Admin renames the device so it uses the company standard naming format, and then installs the client manually by running CCMSetup with the following command from a mapped drive that holds the client source files: CCMSetup. This command installs the client, assigns the client to the management point that has the intranet FQDN of mpserver.

The Admin knows that it always takes a while for clients to install and send back their status to the site. So the Admin waits before they confirm that the clients successfully install, assign to the site, and appear as clients in the collection that they created for Windows Embedded devices. As additional confirmation, the Admin checks the properties of Configuration Manager in Control Panel on the devices and compares them to standard Windows computers that are managed by the site.

Confident that the clients are successfully installed, assigned, and receiving client policy from the management point, the Admin then manually enables the write filters by following the instructions from the OEM. How to deploy clients to Windows computers. How to assign clients to a site. Now that the Configuration Manager client is installed on the Windows Embedded devices, the Admin confirms that they can manage them in the same way as they manage the standard Windows clients.

For example, from the Configuration Manager console, the Admin can remotely manage them by using remote control, initiate client policy for them, and view client properties and hardware inventory. Because these devices are joined to an Active Directory domain, the Admin does not have to manually approve them as trusted clients and confirms from the Configuration Manager console that they are approved. For more information, see How to manage clients. To install the interactive presentation software, the Admin runs the Deploy Software Wizard and configures a required application.

On the User Experience page of the wizard, in the Write filter handling for Windows Embedded devices section, they accept the default option that selects Commit changes at deadline or during a maintenance window requires restarts. The Admin keeps this default option for write filters to ensure that the application persists after a restart, so that it is always available to the visitors using the kiosks.

The daily maintenance window provides a safe period during which the restarts for installation and any updates can occur. For more information, see How to deploy applications with Configuration Manager. They select the Definition Updates template to prepopulate the wizard with settings that are appropriate for Endpoint Protection. Deadline behavior : The Software Installation check box is not selected. Write filter handling for Windows Embedded devices : The Commit changes at deadline or during a maintenance window requires restarts check box is not selected.

The Admin keeps these default settings. Together, these two options with this configuration allow any software update definitions for Endpoint Protection to be installed in the overlay during the day and not wait to be installed and committed during the maintenance window.

This configuration best meets the company security policy for computers to run up-to-date antimalware protection. Unlike software installations for applications, software update definitions for Endpoint Protection can occur very frequently, even multiple times a day. They are often small files.

For these types of security-related deployments, it can often be beneficial to always install to the overlay rather than wait until the maintenance window. The Configuration Manager client will quickly re-install the software definition updates if the device restarts because this action initiates an evaluation check and does not wait until the next scheduled evaluation.

The Admin decides to configure a maintenance task that periodically commits all changes on the overlay. This task is to support the software update definitions deployment, to reduce the number of updates that accumulate and must be installed again, each time the device restarts. In the Admin’s experience, this helps the antimalware programs run more efficiently. These software update definitions would be automatically committed to the image if the embedded devices ran another management task that supported committing the changes.

For example, installing a new version of the interactive presentation software would also commit the changes for software update definitions. Or, installing standard software updates every month that install during the maintenance window could also commit the changes for software update definitions. However, in this scenario, where standard software updates do not run and the interactive presentation software is unlikely to be updated very often, it might be months before the software definition updates are automatically committed to the image.

The Admin first creates a custom task sequence that has no settings other than the name. They run the Create Task Sequence Wizard:. On the Task Sequence Information page, the Admin enters Maintenance task to commit changes on embedded devices for the task sequence name, and then clicks Next.

On the Summary page, the Admin selects Next , and completes the wizard. The Admin then deploys this custom task sequence to the Windows Embedded devices collection, and configures the schedule to run every month. As part of the deployment settings, they select the Commit changes at deadline or during a maintenance window requires restarts check box to persist the changes after a restart.

To configure this deployment, the Admin selects the custom task sequence that they just created, and then on the Home tab, in the Deployment group, they click Deploy to start the Deploy Software Wizard:. On the General page, the Admin selects the Windows Embedded devices collection, and then clicks Next. On the Scheduling page, the Admin clicks New to specify a weekly schedule during the maintenance window, and then clicks Next.

For more information, see Manage task sequences to automate tasks. For the kiosks to run automatically, the Admin writes a script to configure the devices for the following settings:. The Admin uses packages and programs to deploy this script to the Windows Embedded devices collection. When the Admin runs the Deploy Software Wizard, they again select the Commit changes at deadline or during a maintenance window requires restarts check box to persist the changes after a restart.

For more information, see Packages and programs. The following morning, the Admin checks the Windows Embedded devices. They confirm the following:. How to monitor Endpoint Protection. Monitor applications with Configuration Manager. The Admin monitors the kiosks and reports the successful management of them to their manager.

As a result, 20 kiosks are ordered for the visitor center. To avoid the manual installation of the Configuration Manager client, which requires manually disabling and then enabling the write filters, the Admin ensures that the order includes a customized image that already includes the installation and site assignment of the Configuration Manager client.

In addition, the devices are named according to the company naming format. The kiosks are delivered to the visitor center a week before it opens. During this time, the kiosks are connected to the network, all device management for them is automatic, and no local administrator is required.

The Admin confirms that the kiosks are functioning as required:. The clients on the kiosks complete site assignment and download the trusted root key from Active Directory Domain Services.

The clients on the kiosks are automatically added to the Windows Embedded devices collection and configured with the maintenance window.

The Endpoint Protection client is installed and has the latest software update definitions for antimalware protection. After this initial setup, any restarts that might be required for updates occur only when the visitor center is closed. Feedback will be sent to Microsoft: By pressing the submit button, your feedback will be used to improve Microsoft products and services. Privacy policy. Skip to main content. Contents Exit focus mode. The Admin then configures a custom device client setting to install the Endpoint Protection client by selecting Yes for the following settings, and then deploys this custom client setting to the Windows Embedded device collection: Install Endpoint Protection client on client computers For Windows Embedded devices with write filters, commit Endpoint Protection client installation requires restart Allow Endpoint Protection client installation and restart to be performed outside maintenance windows When the Configuration Manager client is installed, these settings install the Endpoint Protection client and ensure that it is persisted in the operating system as part of the installation, rather than written to the overlay only.